Please use this identifier to cite or link to this item: http://hdl.handle.net/11718/20473
Title: Environment control of greenhouse at Bhujodi
Authors: Sharan, Girja
Pilare, Vasant R.
Keywords: Greenhouse management;Environmental aspect
Issue Date: 1-Nov-1998
Publisher: Indian Institute of Management Ahmedabad
Series/Report no.: WP;1480
Abstract: This write-up contains air temperature data and preliminary analysis of cooling requirement for greenhouse at Bhujodi. Examination of the temperature data showed that night time temperatures remain high enough most of the time. Heating of the greenhouse perhaps will not be required. Day time temperatures on the other hand, remains high enough most of the time to require cooling. Forced ventilation does seem effective, but only for part of day. Evaporation cooling and misting appears necessary. Design of fan-pad system was carried out. It consists of two fans (size 24 inch and 1/3 HP) and cross fluted pad (area 5m2). Water loss is estimated to be about 1000 lit/day in the cooling system, which works out to about 10 lit/m2 of floor are per day.
URI: http://hdl.handle.net/11718/20473
Appears in Collections:Working Papers

Files in This Item:
File Description SizeFormat 
wp 1998_1480.pdfWP_1998_14801.23 MBAdobe PDFView/Open