Please use this identifier to cite or link to this item: http://hdl.handle.net/11718/25174
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPerez-Lorenzo L.J.
dc.contributor.authorKhanna V.
dc.contributor.authorMeena T.
dc.contributor.authorSchmitt J.J.
dc.contributor.authorde la Mora J.F.
dc.date.accessioned2022-02-11T10:13:46Z-
dc.date.available2022-02-11T10:13:46Z-
dc.date.issued2020
dc.identifier.citationPerez-Lorenzo, L. J., Khanna, V., Meena, T., Schmitt, J. J., & de la Mora, J. F. (2019). A high resolution DMA covering the 1�?nm size range. Https://Doi.Org/10.1080/02786826.2019.1684433, 54(1), 128�2. https://doi.org/10.1080/02786826.2019.1684433
dc.identifier.issn2786826
dc.identifier.urihttps://www.doi.org/10.1080/02786826.2019.1684433
dc.identifier.urihttp://hdl.handle.net/11718/25174-
dc.description.abstractA differential mobility analyzer for high-mobility resolution (1/FWHM?30) classification of 1� nm particles is designed to analyze viral particles. Inner and outer electrode radii of 1.01 and 2 cm (at the outlet slit) and a 11.6 cm long column achieve this range at a sheath gas flow (Q) and aerosol flow (q) of 30 and 1 L/min. Turbulent transition potentially resulting from this substantial length combined with high sheath gas flow rates (Q?1000 Lit/min) required to classify 1 nm particles is avoided by stabilizing the flow via a continuous acceleration with a conical inner electrode (1� half-angle). High axisymmetry of the aerosol flow as it joins the sheath gas is achieved by injecting it through a circularizer ring with 24 symmetrically spaced orifices. The sheath flow is laminarized with two pre-laminarization schemes, three laminarization screens, and an inlet trumpet with an area ?3 times the analyzer channel throat area. The instrument is tested with singly charged monomobile cluster ions produced by a bipolar electrospray source. A resolving power of 29 is measured at the highest flow rate reached, with a trend towards even higher resolution if either Q or the monomobile particle size could be increased. This performance indicates that the electrode concentricity is excellent and the flow highly stable. Tests carried out at limited resolution (set below 16 by a protein test aerosol) with the modest Q/q?30 values required to classify 70 nm particles indicate that the DMA response is close to ideal at Q = 151, 110, and 47 Lit/min. Copyright � 2019 American Association for Aerosol Research. � 2019, � 2019 American Association for Aerosol Research.
dc.description.sponsorship1 R43 GM131542-01A1;燦ational Institute of General Medical Sciences,燦IGMS
dc.language.isoen_US
dc.publisherTaylor and Francis Inc.
dc.relation.ispartofAerosol Science and Technology
dc.subjectJason Olfert
dc.titleA high resolution DMA covering the 1� nm size range
dc.typeArticle
dc.rights.licenseCC BY-NC, CC BY-NC-ND
dc.contributor.affiliationDepartment of Mechanical Engineering and Materials Science, Yale University, New Haven, CT, United States
dc.contributor.affiliationNanoEngineering Corporation, Boca Raton, FL, United States
dc.contributor.affiliationIndian Institute of Management Ahmedabad, Vastrapur, Ahmedabad, Gujarat, India
dc.contributor.institutionauthorPerez-Lorenzo, L.J., Department of Mechanical Engineering and Materials Science, Yale University, New Haven, CT, United States
dc.contributor.institutionauthorKhanna, V., Department of Mechanical Engineering and Materials Science, Yale University, New Haven, CT, United States
dc.contributor.institutionauthorMeena, T., Department of Mechanical Engineering and Materials Science, Yale University, New Haven, CT, United States, Indian Institute of Management Ahmedabad, Vastrapur, Ahmedabad, Gujarat, India
dc.contributor.institutionauthorSchmitt, J.J., NanoEngineering Corporation, Boca Raton, FL, United States
dc.contributor.institutionauthorde la Mora, J.F., Department of Mechanical Engineering and Materials Science, Yale University, New Haven, CT, United States
dc.description.scopusid57211860569
dc.identifier.doi10.1080/02786826.2019.1684433
dc.identifier.endpage142
dc.identifier.startpage128
dc.identifier.issue1
dc.identifier.volume54
Appears in Collections:Open Access Journal Articles

Files in This Item:
File SizeFormat 
a_high_resolution_2020.pdf2.19 MBAdobe PDFView/Open


Items in IIMA Institutional Repository are protected by copyright, with all rights reserved, unless otherwise indicated.