Performance of Greenhouse Coupled to Earth-Tube-Heat-Exchanger in Closed-Loop Mode
(2009-09-05)
An experimental greenhouse coupled to an Earth Tube Heat Exchanger (ETHE) in closed-loop mode has been installed at Kothara (23o 40' N 72o 38' E), India. Area is hot and extremely arid. ETHE is used to warm the greenhouse ...
Soil temperature regime at Ahmedabad
(2002-10-21)
A 3-m deep temperature probe was installed at the campus of Indian Institute
of Management, Ahmedabad in August, 1999. Probe has five resistance type